26
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found

      A New Cardiology Patient Simulator

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We report a new cardiology patient simulator developed through the application of new digital computer technology, capable of playing back selected physical findings (jugular-venous waves, arterial pulses of carotid, brachial, radial and femoral arteries, and cardiac impulses), as well as cardiac sounds, murmurs and respiratory sounds that have been prerecorded from actual patients. The examining physician uses an ordinary type of stethoscope. Four built-in speakers are located in the human-sized mannequin at the classic auscultatory sites (aortic, pulmonic, tricuspid and mitral). This compact and portable educational apparatus should facilitate medical training in the bedside cardiac examination, of physicians, medical students, nurses and paramedics throughout the world.

          Related collections

          Author and article information

          Journal
          CRD
          Cardiology
          10.1159/issn.0008-6312
          Cardiology
          S. Karger AG
          0008-6312
          1421-9751
          1997
          1997
          19 November 2008
          : 88
          : 5
          : 408-413
          Affiliations
          aJapanese Educational Clinical Cardiology Society, Osaka, bDepartment of Mechanical Informatics, Graduate School of Information Science and Engineering, Tokyo Institute of Technology, Tokyo, and cDepartment of Medical Educational Instrument, Kyoto Kagaku Co. Ltd., Kyoto, Japan
          Article
          177369 Cardiology 1997;88:408–413
          10.1159/000177369
          9286501
          5216aad3-b20b-48f4-b2d0-130984aba166
          © 1997 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          : 19 August 1996
          : 21 August 1996
          Page count
          Pages: 6
          Categories
          General Cardiology

          General medicine,Neurology,Cardiovascular Medicine,Internal medicine,Nephrology
          Cardiac impulses,Digital and computer technology,Arterial pulses,Mechanocardiogram,Cardiology patient simulator,Jugular-venous waves,Auscultatory sites

          Comments