      Contrast-Enhanced MicroCT for Virtual 3D Anatomical Pathology of Biological Tissues: A Literature Review

      1 , 2 , 1 , 3 , 4 , 1 , 4 , 5
      Contrast Media & Molecular Imaging
      Hindawi Limited

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To date, the combination of histological sectioning, staining, and microscopic assessment of the 2D sections is still the golden standard for structural and compositional analysis of biological tissues. X-ray microfocus computed tomography (microCT) is an emerging 3D imaging technique with high potential for 3D structural analysis of biological tissues with a complex and heterogeneous 3D structure, such as the trabecular bone. However, its use has been mostly limited to mineralized tissues because of the inherently low X-ray absorption of soft tissues. To achieve sufficient X-ray attenuation, chemical compounds containing high atomic number elements that bind to soft tissues have been recently adopted as contrast agents (CAs) for contrast-enhanced microCT (CE-CT); this novel technique is very promising for quantitative “virtual” 3D anatomical pathology of both mineralized and soft biological tissues. In this paper, we provided a review of the advances in CE-CT since the very first reports on the technology to date. Perfusion CAs for in vivo imaging have not been discussed, as the focus of this review was on CAs that bind to the tissue of interest and that are, thus, used for ex vivo imaging of biological tissues. As CE-CT has mostly been applied for the characterization of musculoskeletal tissues, we have put specific emphasis on these tissues. Advantages and limitations of multiple CAs for different musculoskeletal tissues have been highlighted, and their reproducibility has been discussed. Additionally, the advantages of the “full” 3D CE-CT information have been pinpointed, and its importance for more detailed structural, spatial, and functional characterization of the tissues of interest has been shown. Finally, the remaining challenges that are still hampering a broader adoption of CE-CT have been highlighted, and suggestions have been made to move the field of CE-CT imaging one step further towards a standard accepted tool for quantitative virtual 3D anatomical pathology.

          Related collections

          Most cited references54

          • Record: found
          • Abstract: not found
          • Article: not found

          X-ray-computed tomography contrast agents.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The microstructure and micromechanics of the tendon–bone insertion

            High-resolution imaging, composition analysis and mechanical testing provide a new insight into the structure and function of the Achilles enthesis.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Concentration-dependent specimen shrinkage in iodine-enhanced microCT.

              Iodine potassium iodide (I2 KI) solution can be employed as a contrast agent for the visualisation of soft tissue structures in micro-computed tomography studies. This technique provides high resolution images of soft tissue non-destructively but initial studies suggest that the stain can cause substantial specimen shrinkage. The degree of specimen shrinkage, and potential deformation, is an important consideration when using the data for morphological studies. Here we quantify the macroscopic volume changes in mouse skeletal muscle, cardiac muscle and cerebellum as a result of immersion in the common fixatives 10% phosphate-buffered formal saline, 70% ethanol and 3% glutaraldehyde, compared with I2 KI staining solution at concentrations of 2, 6, 10 and 20%. Immersion in the I2 KI solution resulted in dramatic changes of tissue volume, which were far larger than the shrinkage from formalin fixation alone. The degree of macroscopic change was most dependent upon the I2 KI concentration, with severe shrinkage of 70% seen in solutions of 20% I2 KI after 14 days' incubation. When using this technique care needs to be taken to use the lowest concentration that will give adequate contrast to minimise artefacts due to shrinkage. © 2013 Anatomical Society.
                Bookmark

                Author and article information

                Journal
                Contrast Media & Molecular Imaging
                Contrast Media & Molecular Imaging
                Hindawi Limited
                1555-4309
                1555-4317
                February 28 2019
                February 28 2019
                : 2019
                : 1-9
                Affiliations
                [1 ]Prometheus, Division of Skeletal Tissue Engineering, KU Leuven, Leuven, Belgium
                [2 ]Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
                [3 ]Molecular Design and Synthesis, Department of Chemistry, KU Leuven, Leuven, Belgium
                [4 ]Biomechanics Lab, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
                [5 ]Department Materials Engineering, KU Leuven, Leuven, Belgium
                Article
                10.1155/2019/8617406
                dbc5e573-da2c-4b27-9a38-8f3eadb4f755
                © 2019

                http://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article