      Development of an immunochromatographic assay based on dense granule protein 7 for serological detection of Toxoplasma gondii infection.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Dense granule antigen proteins derived from Toxoplasma gondii (TgGRAs) are potential antigens for the development of diagnostic tools. TgGRA7 and TgGRA14 were detected in the peritoneal fluid of T. gondii-infected mice, suggesting that TgGRAs may be highly antigenic proteins. Here, TgGRA7 and TgGRA14 were evaluated as candidates for the development of a marker for a rapid diagnostic test. The specificity and sensitivity of purified recombinant proteins of TgGRA7 and TgGRA14 were compared in an indirect enzyme-linked immunosorbent assay (iELISA) using a series of serum samples from T. gondii-experimentally infected mice and using recombinant T. gondii major surface antigen 2 (TgSAG2) as a reference control. The iELISA with TgGRA7 showed the greatest diagnostic accuracy and could detect anti-TgGRA7 antibody in acute and chronic infections. A total of 59 field samples from pigs were also examined by the iELISAs, and the results compared with those of the latex agglutination test (LAT). Among the three recombinant antigens, TgGRA7 had the highest rates of positivity, with significant concordance (88.14) and kappa value (0.76) in comparison with the results using LAT. Furthermore, an immunochromatographic test (ICT) based on recombinant TgGRA7 was developed for rapid detection of antibodies to the infection. The ICT differentiated clearly between sera from T. gondii-infected mice and uninfected or Neospora caninum-infected mice. Pig sera were examined with the ICT, and the results compared favorably with those of LAT and iELISA for TgGRA7, with kappa values of 0.66 and 0.70 to 0.79, respectively. These data suggest that the ICT based on TgGRA7 is a promising diagnostic tool for routine testing in the clinic and mass screening of samples in the field.

          Related collections

          Author and article information

          Journal
          Clin. Vaccine Immunol.
          Clinical and vaccine immunology : CVI
          American Society for Microbiology
          1556-679X
          1556-679X
          Apr 2013
          : 20
          : 4
          Affiliations
          [1 ] National Research Center for Protozoan Diseases, Obihiro University of Agriculture and Veterinary Medicine, Inada-cho, Obihiro, Hokkaido, Japan.
          Article
          CVI.00747-12
          10.1128/CVI.00747-12
          3623415
          23408523
          04fe8140-86c7-44a0-a2a9-596b23d3cc9d
          History

          Comments

          Comment on this article