9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Hematopoietic SCT with cryopreserved grafts: adverse reactions after transplantation and cryoprotectant removal before infusion.

      1 , 2 , 1
      Bone marrow transplantation
      Springer Nature

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Transplantation of hematopoietic stem cells (HSCs) has been successfully developed as a part of treatment protocols for a large number of clinical indications, and cryopreservation of both autologous and allogeneic sources of HSC grafts is increasingly being used to facilitate logistical challenges in coordinating the collection, processing, preparation, quality control testing and release of the final HSC product with delivery to the patient. Direct infusion of cryopreserved cell products into patients has been associated with the development of adverse reactions, ranging from relatively mild symptoms to much more serious, life-threatening complications, including allergic/gastrointestinal/cardiovascular/neurological complications, renal/hepatic dysfunctions, and so on. In many cases, the cryoprotective agent (CPA) used-which is typically dimethyl sulfoxide (DMSO)-is believed to be the main causal agent of these adverse reactions and thus many studies recommend depletion of DMSO before cell infusion. In this paper, we will briefly review the history of HSC cryopreservation, the side effects reported after transplantation, along with advances in strategies for reducing the adverse reactions, including methods and devices for removal of DMSO. Strategies to minimize adverse effects include medication before and after transplantation, optimizing the infusion procedure, reducing the DMSO concentration or using alternative CPAs for cryopreservation and removing DMSO before infusion. For DMSO removal, besides the traditional and widely applied method of centrifugation, new approaches have been explored in the past decade, such as filtration by spinning membrane, stepwise dilution-centrifugation using rotating syringe, diffusion-based DMSO extraction in microfluidic channels, dialysis and dilution-filtration through hollow-fiber dialyzers and some instruments (CytoMate, Sepax S-100, Cobe 2991, microfluidic channels, dilution-filtration system, etc.) as well. However, challenges still remain: development of the optimal (fast, safe, simple, automated, controllable, effective and low cost) methods and devices for CPA removal with minimum cell loss and damage remains an unfilled need.

          Related collections

          Author and article information

          Journal
          Bone Marrow Transplant.
          Bone marrow transplantation
          Springer Nature
          1476-5365
          0268-3369
          Apr 2014
          : 49
          : 4
          Affiliations
          [1 ] Department of Mechanical Engineering and Department of Bioengineering, University of Washington, Seattle, WA, USA.
          [2 ] Division of Clinical Research, Fred Hutchinson Cancer Research Center, Seattle, WA, USA.
          Article
          bmt2013152 NIHMS685156
          10.1038/bmt.2013.152
          4420483
          24076548
          06c44732-a470-40a8-9a67-4fde28741e38
          History

          Comments

          Comment on this article