      Thrombogenicity assessment of Pipeline Flex, Pipeline Shield, and FRED flow diverters in an in vitro human blood physiological flow loop model

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Endovascular treatment of intracranial aneurysms with endoluminal flow diverters (single or multiple) has proven to be clinically safe and effective, but is associated with a risk of thromboembolic complications. Recently, a novel biomimetic surface modification with covalently bound phosphorylcholine (Shield Technology™) has shown to reduce the material thrombogenicity of the Pipeline flow diverter. Thrombogenicity of Pipeline Flex, Pipeline Shield, and Flow Redirection Endoluminal Device (FRED) in the presence of human blood under physiological flow conditions—in addition to relative increase in thrombogenicity with multiple devices—remains unknown and was investigated here. Thrombin generation (mean ± SD; μg/mL; thrombin–antithrombin complex or TAT) was measured as FRED (30.3 ± 2.9), Pipeline (13.9 ± 4.4), Pipeline Shield (0.4 ± 0.3), and negative control (no device; 0.1 ± 0.0). Platelet activation (mean ± SD; IU/μL; beta‐thromboglobulin or βTG) was measured as FRED (148 ± 45), Pipeline (92.8 ± 41), Pipeline Shield (16.2 ± 3.5), and negative control (2.70 ± 0.16). FRED was significantly more thrombogenic than Pipeline and Pipeline Shield (p < 0.05) for TAT. Additionally, Pipeline Shield had significantly lower TAT and βTG than the other devices tested (p < 0.05) and these were comparable to the negative control (p > 0.05). TAT and βTG scaled proportionately with multiple Pipeline devices ( N = 6) but was unaffected by multiple Pipeline Shield ( N = 6) devices—the latter being statistically similar to negative control (p > 0.05). © 2018 The Authors. Journal Of Biomedical Materials Research Part A Published By Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 3195–3202, 2018.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: not found

          Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.

          To evaluate the safety and effectiveness of the Pipeline Embolization Device (PED; ev3/Covidien, Irvine, Calif) in the treatment of complex intracranial aneurysms. The Pipeline for Uncoilable or Failed Aneurysms is a multicenter, prospective, interventional, single-arm trial of PED for the treatment of uncoilable or failed aneurysms of the internal carotid artery. Institutional review board approval of the HIPAA-compliant study protocol was obtained from each center. After providing informed consent, 108 patients with recently unruptured large and giant wide-necked aneurysms were enrolled in the study. The primary effectiveness endpoint was angiographic evaluation that demonstrated complete aneurysm occlusion and absence of major stenosis at 180 days. The primary safety endpoint was occurrence of major ipsilateral stroke or neurologic death at 180 days. PED placement was technically successful in 107 of 108 patients (99.1%). Mean aneurysm size was 18.2 mm; 22 aneurysms (20.4%) were giant (>25 mm). Of the 106 aneurysms, 78 met the study's primary effectiveness endpoint (73.6%; 95% posterior probability interval: 64.4%-81.0%). Six of the 107 patients in the safety cohort experienced a major ipsilateral stroke or neurologic death (5.6%; 95% posterior probability interval: 2.6%-11.7%). PED offers a reasonably safe and effective treatment of large or giant intracranial internal carotid artery aneurysms, demonstrated by high rates of complete aneurysm occlusion and low rates of adverse neurologic events; even in aneurysms failing previous alternative treatments.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The pipeline embolization device for the intracranial treatment of aneurysms trial.

            Endoluminal reconstruction with flow diverting devices represents a novel constructive technique for the treatment of cerebral aneurysms. We present the results of the first prospective multicenter trial of a flow-diverting construct for the treatment of intracranial aneurysms. Patients with unruptured aneurysms that were wide-necked (> 4 mm), had unfavorable dome/neck ratios (<1.5), or had failed previous therapy were enrolled in the PITA trial between January and May 2007 at 4 (3 European and 1 South American) centers. Aneurysms were treated with the PED with or without adjunctive coil embolization. All patients underwent clinical evaluation at 30 and 180 days and conventional angiography 180 days after treatment. Angiographic results were adjudicated by an experienced neuroradiologist at a nonparticipating site. Thirty-one patients with 31 intracranial aneurysms (6 men; 42-76 years of age; average age, 54.6 years) were treated during the study period. Twenty-eight aneurysms arose from the ICA (5 cavernous, 15 parophthalmic, 4 superior hypophyseal, and 4 posterior communicating segments), 1 from the MCA, 1 from the vertebral artery, and 1 from the vertebrobasilar junction. Mean aneurysm size was 11.5 mm, and mean neck size was 5.8 mm. Twelve (38.7%) aneurysms had failed (or recurred after) a previous endovascular treatment. PED placement was technically successful in 30 of 31 patients (96.8%). Most aneurysms were treated with either 1 (n = 18) or 2 (n = 11) PEDs. Fifteen aneurysms (48.4%) were treated with a PED alone, while 16 were treated with both PED and embolization coils. Two patients experienced major periprocedural stroke. Follow-up angiography demonstrated complete aneurysm occlusion in 28 (93.3%) of the 30 patients who underwent angiographic follow-up. No significant in-construct stenosis (≥ 50%) was identified at follow-up angiography. Intracranial aneurysm treatment with the PED is technically feasible and can be achieved with a safety profile analogous to that reported for stent-supported coil embolization. PED treatment elicited a very high rate (93%) of complete angiographic occlusion at 6 months in a population of the most challenging anatomic subtypes of cerebral aneurysms.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Interspecies differences in coagulation profile.

              Many animals are used in research on blood coagulation and fibrinolysis, but the relevance of animal models to human health is often questioned because of differences between species. The objective was to find an appropriate animal species, which mimics the coagulation profile in humans most adequately. Species differences in the coagulation profile with and without thrombin stimulation in vitro were assessed in whole blood by Rotation Thromboelastometry (ROTEM). Endogenous thrombin generation was measured in platelet-poor plasma. Measurements were performed in blood from five different species: humans, rats, pigs, sheep and rabbits. In humans and sheep, the clotting time (ROTEM) was in the same range with or without thrombin stimulation and a 100-fold lower dose of thrombin (0.002 IU) was required to cause a shortening in the clotting time as compared to rats, pigs and rabbits (0.2 IU) (p<0.05). Similarly, the endogenous thrombin potential (ETP) was in the same range in humans and sheep. The maximum clot firmness with or without thrombin stimulation was similar in rabbits and humans. The maximum lysis with or without thrombin stimulation was similar in humans and pigs. Significant species differences exist in the coagulation profile with or without thrombin stimulation. Most importantly, sheep had a clotting time most similar to humans and could thus be a suitable species for translational coagulation studies. Moreover, our findings confirm the potential usefulness of pigs as an experimental species to study fibrinolytic pathway and support the usefulness of rabbits as a species for examining platelets.
                Bookmark

                Author and article information

                Contributors
                michael.wolf@medtronic.com
                Journal
                J Biomed Mater Res A
                J Biomed Mater Res A
                10.1002/(ISSN)1552-4965
                JBM
                Journal of Biomedical Materials Research. Part a
                John Wiley & Sons, Inc. (Hoboken, USA )
                1549-3296
                1552-4965
                22 September 2018
                December 2018
                : 106
                : 12 ( doiID: 10.1002/jbm.a.v106.12 )
                : 3195-3202
                Affiliations
                [ 1 ] Medtronic Neurovascular Irvine California
                [ 2 ] Medtronic Core Technologies Minneapolis Minnesota
                Author notes
                [*] [* ] Correspondence to: M. F. Wolf; e‐mail: michael.wolf@ 123456medtronic.com
                Article
                JBMA36514
                10.1002/jbm.a.36514
                6282594
                30242950
                0d460405-eb26-42f2-a53d-78e7689a8b33
                © 2018 The Authors. Journal of Biomedical Materials Research Part A published by Wiley Periodicals, Inc

                This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.

                History
                : 22 May 2018
                : 21 June 2018
                : 05 July 2018
                Page count
                Figures: 5, Tables: 2, Pages: 8, Words: 5602
                Categories
                Original Article
                Original Articles
                Custom metadata
                2.0
                jbma36514
                December 2018
                Converter:WILEY_ML3GV2_TO_NLMPMC version:version=5.5.3 mode:remove_FC converted:06.12.2018

                Biomaterials & Organic materials
                flow diversion,intracranial aneurysm,thrombosis,surface modification,phosphorylcholine

                Comments

                Comment on this article