      Monolithic polymeric porous superhydrophobic material with pneumatic plastron stabilization for functionally durable drag reduction in blood-contacting biomedical applications

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Superhydrophobic (SHP) surfaces can provide substantial reductions in flow drag forces and reduce blood damage in cardiovascular medical devices. However, strategies for functional durability are necessary, as many SHP surfaces have low durability under abrasion or strong fluid jetting or eventually lose their air plastron and slip-flow capabilities due to plastron gas dissolution, high fluid pressure, or fouling. Here, we present a functional material that extends the functional durability of superhydrophobic slip flow. Facile modification of a porous superhydrophobic polytetrafluoroethylene (PTFE, Teflon) foam produced suitable surface structures to enable fluid slip flow and resist protein fouling. Its monolithic nature offered abrasion durability, while its porosity allowed pressurized air to be supplied to resist fluid impalement and to replenish the air plastron lost to the fluid through dissolution. Active pore pressure control could resist high fluid pressures and turbulent flow conditions across a wide range of applied pressures. The pneumatically stabilized material yielded large drag reductions (up to 50%) even with protein fouling, as demonstrated from high-speed water jetting and closed loop pressure drop tests. Coupled with its high hemocompatibility and impaired protein adsorption, this easily fabricated material can be viable for incorporation into blood-contacting medical devices.

          Related collections

          Most cited references60

          • Record: found
          • Abstract: found
          • Article: not found

          Mechanically durable superhydrophobic surfaces.

          Development of durable non-wetting surfaces is hindered by the fragility of the microscopic roughness features that are necessary for superhydrophobicity. Mechanical wear on superhydrophobic surfaces usually shows as increased sticking of water, leading to loss of non-wettability. Increased wear resistance has been demonstrated by exploiting hierarchical roughness where nanoscale roughness is protected to some degree by large scale features, and avoiding the use of hydrophilic bulk materials is shown to help prevent the formation of hydrophilic defects as a result of wear. Additionally, self-healing hydrophobic layers and roughness patterns have been suggested and demonstrated. Nevertheless, mechanical contact not only causes damage to roughness patterns but also surface contamination, which shortens the lifetime of superhydrophobic surfaces in spite of the self-cleaning effect. The use of photocatalytic effect and reduced electric resistance have been suggested to prevent the accumulation of surface contaminants. Resistance to organic contaminants is more challenging, however, oleophobic surface patterns which are non-wetting to organic liquids have been demonstrated. While the fragility of superhydrophobic surfaces currently limits their applicability, development of mechanically durable surfaces will enable a wide range of new applications in the future. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling.

            Thrombosis and biofouling of extracorporeal circuits and indwelling medical devices cause significant morbidity and mortality worldwide. We apply a bioinspired, omniphobic coating to tubing and catheters and show that it completely repels blood and suppresses biofilm formation. The coating is a covalently tethered, flexible molecular layer of perfluorocarbon, which holds a thin liquid film of medical-grade perfluorocarbon on the surface. This coating prevents fibrin attachment, reduces platelet adhesion and activation, suppresses biofilm formation and is stable under blood flow in vitro. Surface-coated medical-grade tubing and catheters, assembled into arteriovenous shunts and implanted in pigs, remain patent for at least 8 h without anticoagulation. This surface-coating technology could reduce the use of anticoagulants in patients and help to prevent thrombotic occlusion and biofouling of medical devices.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Medical device-induced thrombosis: what causes it and how can we prevent it?

              Blood-contacting medical devices, such as vascular grafts, stents, heart valves, and catheters, are often used to treat cardiovascular diseases. Thrombus formation is a common cause of failure of these devices. This study (i) examines the interface between devices and blood, (ii) reviews the pathogenesis of clotting on blood-contacting medical devices, (iii) describes contemporary methods to prevent thrombosis on blood-contacting medical devices, (iv) explains why some anticoagulants are better than others for prevention of thrombosis on medical devices, and (v) identifies future directions in biomaterial research for prevention of thrombosis on blood-contacting medical devices.
                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                Journal
                NPG Asia Materials
                NPG Asia Mater
                Springer Science and Business Media LLC