1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Development of a magnetoinductive lens for magnetic resonance imaging

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references15

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Magnetic Metamaterial Superlens for Increased Range Wireless Power Transfer

          The ability to wirelessly power electrical devices is becoming of greater urgency as a component of energy conservation and sustainability efforts. Due to health and safety concerns, most wireless power transfer (WPT) schemes utilize very low frequency, quasi-static, magnetic fields; power transfer occurs via magneto-inductive (MI) coupling between conducting loops serving as transmitter and receiver. At the “long range” regime – referring to distances larger than the diameter of the largest loop – WPT efficiency in free space falls off as (1/d)6; power loss quickly approaches 100% and limits practical implementations of WPT to relatively tight distances between power source and device. A “superlens”, however, can concentrate the magnetic near fields of a source. Here, we demonstrate the impact of a magnetic metamaterial (MM) superlens on long-range near-field WPT, quantitatively confirming in simulation and measurement at 13–16 MHz the conditions under which the superlens can enhance power transfer efficiency compared to the lens-less free-space system.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Experimental demonstration of a mu=-1 metamaterial lens for magnetic resonance imaging

            In this work a mu=-1 metamaterial (MM) lens for magnetic resonance imaging (MRI) is demonstrated. MRI uses surface coils to detect the radiofrequency(RF) energy absorbed and emitted by the nuclear spins in the imaged object. The proposed MM lens manipulates the RF field detected by these surface coils, so that the coil sensitivity and spatial localization is substantially improved. Beyond this specific application, we feel that the reported results are the experimental confirmation of a new concept for the manipulation of RF field in MRI, which paves the way to many other interesting applications.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Near-field enhancement and imaging in double planar polariton-resonant structures

              , , (2003)
              It is shown that a system of two coupled planar material sheets possessing surface mode (polariton) resonances can be used for the purpose of evanescent field restoration and, thus, for the sub-wavelength near-field imaging. The sheets are placed in free space so that they are parallel and separated by a certain distance. Due to interaction of the resonating surface modes (polaritons) of the sheets an exponential growth in the amplitude of an evanescent plane wave coming through the system can be achieved. This effect was predicted earlier for backward-wave (double-negative or Veselago) slab lenses. The alternative system considered here is proved to be realizable at microwaves by grids or arrays of resonant particles. The necessary electromagnetic properties of the resonating grids and the particles are investigated and established. Theoretical results are supported by microwave experiments that demonstrate amplification of evanescent modes.
                Bookmark

                Author and article information

                Journal
                IEEE Instrumentation & Measurement Magazine
                IEEE Instrum. Meas. Mag.
                Institute of Electrical and Electronics Engineers (IEEE)
                1094-6969
                December 2017
                December 2017
                : 20
                : 6
                : 56-60
                Article
                10.1109/MIM.2017.8121953
                15d318ef-003f-4f73-b25d-bed769071b10
                © 2017
                History

                Comments

                Comment on this article