6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Functional alignment achieves soft-tissue balance in total knee arthroplasty as measured with quantitative sensor-guided technology

      1 , 2 , 1 , 2 , 1 , 1 , 2
      The Bone & Joint Journal
      British Editorial Society of Bone & Joint Surgery

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Aims

          Total knee arthroplasty (TKA) using functional alignment aims to implant the components with minimal compromise of the soft-tissue envelope by restoring the plane and obliquity of the non-arthritic joint. The objective of this study was to determine the effect of TKA with functional alignment on mediolateral soft-tissue balance as assessed using intraoperative sensor-guided technology.

          Methods

          This prospective study included 30 consecutive patients undergoing robotic-assisted TKA using the Stryker PS Triathlon implant with functional alignment. Intraoperative soft-tissue balance was assessed using sensor-guided technology after definitive component implantation; soft-tissue balance was defined as intercompartmental pressure difference (ICPD) of < 15 psi. Medial and lateral compartment pressures were recorded at 10°, 45°, and 90° of knee flexion. This study included 18 females (60%) and 12 males (40%) with a mean age of 65.2 years (SD 9.3). Mean preoperative hip-knee-ankle deformity was 6.3° varus (SD 2.7°).

          Results

          TKA with functional alignment achieved balanced medial and lateral compartment pressures at 10° (25.0 psi (SD 6.1) vs 23.1 psi (SD 6.7), respectively; p = 0.140), 45° (21.4 psi (SD 5.9) vs 20.6 psi (SD 5.9), respectively; p = 0.510), and 90° (21.2 psi (SD 7.1) vs 21.6 psi (SD 9.0), respectively; p = 0.800) of knee flexion. Mean ICPD was 6.1 psi (SD 4.5; 0 to 14) at 10°, 5.4 psi (SD 3.9; 0 to 12) at 45°, and 4.9 psi (SD 4.45; 0 to 15) at 90° of knee flexion. Mean postoperative limb alignment was 2.2° varus (SD 1.0°).

          Conclusion

          TKA using the functional alignment achieves balanced mediolateral soft-tissue tension through the arc of knee flexion as assessed using intraoperative pressure-sensor technology. Further clinical trials are required to determine if TKA with functional alignment translates to improvements in patient satisfaction and outcomes compared to conventional alignment techniques. Cite this article: Bone Joint J 2021;103-B(3):507–514.

          Related collections

          Most cited references38

          • Record: found
          • Abstract: found
          • Article: not found

          Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?

          Despite substantial advances in primary TKA, numerous studies using historic TKA implants suggest only 82% to 89% of primary TKA patients are satisfied. We reexamined this issue to determine if contemporary TKA implants might be associated with improved patient satisfaction. We performed a cross-sectional study of patient satisfaction after 1703 primary TKAs performed in the province of Ontario. Our data confirmed that approximately one in five (19%) primary TKA patients were not satisfied with the outcome. Satisfaction with pain relief varied from 72-86% and with function from 70-84% for specific activities of daily living. The strongest predictors of patient dissatisfaction after primary TKA were expectations not met (10.7x greater risk), a low 1-year WOMAC (2.5x greater risk), preoperative pain at rest (2.4x greater risk) and a postoperative complication requiring hospital readmission (1.9x greater risk). Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            GRADING OF PATIENTS FOR SURGICAL PROCEDURES

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus.

              Most knee surgeons have believed during TKA neutral mechanical alignment should be restored. A number of patients may exist, however, for whom neutral mechanical alignment is abnormal. Patients with so-called "constitutional varus" knees have had varus alignment since they reached skeletal maturity. Restoring neutral alignment in these cases may in fact be abnormal and undesirable and would likely require some degree of medial soft tissue release to achieve neutral alignment.
                Bookmark

                Author and article information

                Journal
                The Bone & Joint Journal
                The Bone & Joint Journal
                British Editorial Society of Bone & Joint Surgery
                2049-4394
                2049-4408
                March 01 2021
                March 01 2021
                : 103-B
                : 3
                : 507-514
                Affiliations
                [1 ] Department of Trauma and Orthopaedic Surgery, University College London Hospitals, London
                [2 ] Department of Trauma and Orthopaedic Surgery, The Princess Grace Hospital, London, UK
                Article
                10.1302/0301-620X.103B.BJJ-2020-0940.R1
                33467917
                3b517fcc-20e1-4bee-9359-a0bee65e7145
                © 2021

                https://online.boneandjoint.org.uk/TDM

                History

                Comments

                Comment on this article