23
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Determination of selected endocrine disrupting compounds in human fetal and newborn tissues by GC-MS.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Endocrine disrupting compounds (EDCs) include organochlorine pesticides (OCPs), organophosphate pesticides (OPPs), carbamate pesticides, and plasticizers, such as bisphenol A (BPA). They persist in the environment because of their degradation resistance and bioaccumulate in the body tissues of humans and other mammals. Many studies are focused on the possible correlation between in utero exposure to EDCs and adverse health hazards in fetuses and newborns. In the last decade, environmental pollution has been considered a possible trigger for Sudden Infant Death Syndrome (SIDS) and Sudden Intrauterine Unexplained Death Syndrome (SIUDS), the most important death-causing syndromes in fetuses and newborns in developed countries. In this work, a rapid and sensitive analytical method was developed to determine the level of OCPs and OPPs, carbamates, and phenols in human fetal and newborn tissues (liver and brain) and to unveil the possible presence of non-targeted compounds. The target analytes where selected on the basis of their documented presence in the Trentino-Alto Adige region, an intensive agricultural area in northern Italy. A liquid-solid extraction procedure was applied on human and animal tissues and the extracts, after a solid phase extraction (SPE) clean-up procedure, were analyzed by gas chromatography coupled to a quadrupole mass spectrometric detector (GC-qMS). A GC-TOFMS (time-of-flight) instrument, because of its higher full-scan sensitivity, was used for a parallel detection of non-targeted compounds. Method validation included accuracy, precision, detection, and quantification limits (LODs; LOQs), and linearity response using swine liver and lamb brain spiked at different concentrations in the range of 0.4-8000.0 ng/g. The method gave good repeatability and extraction efficiency. Method LOQs ranged from 0.4-4.0 ng/g in the selected matrices. Good linearity was obtained over four orders of magnitude starting from LOQs. Isotopically labeled internal standards were used for quantitative calculations. The method was then successfully applied to the analysis of liver and brain tissues from SIUDS and SIDS victims coming from the above mentioned region.

          Related collections

          Author and article information

          Journal
          Anal Bioanal Chem
          Analytical and bioanalytical chemistry
          Springer Nature America, Inc
          1618-2650
          1618-2642
          May 2014
          : 406
          : 12
          Affiliations
          [1 ] LC-MS Laboratory, DiSTeVA, University of Urbino, Piazza Rinascimento 6, 61029, Urbino, Italy, achille.cappiello@uniurb.it.
          Article
          10.1007/s00216-014-7692-0
          24633505
          6bd15752-22f3-46e3-b4ae-f0b272dd33ea
          History

          Comments

          Comment on this article