      Evaluation of the Separate Equilibrium Processes That Dictate the Upper Detection Limit of Neutral Ionophore-Based Potentiometric Sensors

      ,
      Analytical Chemistry
      American Chemical Society (ACS)

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The upper detection limit of polar ionophore-based ion-selective electrode membranes is predicted by utilizing the coextraction constant of dissociated electrolyte, the stability constant of the ionophore, and the membrane composition. The coextraction constant of dissociated electrolytes into the polar poly(vinyl chloride) membrane plasticized with o-nitrophenyl octyl ether (PVC-NPOE) is here measured by a novel approach. The sandwich membrane technique is utilized, with one membrane segment containing a lipophilic cation exchanger and the other containing an anion exchanger. This yields information about the coextraction constant and the free ion concentrations of the electrolyte in the two segments. Predictions correlate quantitatively with the upper detection limit observed for ion-selective electrodes based on the ionophores valinomycin, tert-butylcalix[4]arene tetraethyl ester, and calcimycin. The difficulties of the prediction of the upper detection limit for nonpolar poly(vinyl chloride) membranes plasticized with bis(2-ethylhexyl sebacate) (PVC-DOS) due to ion association are discussed in detail. A thermodynamic cycle experiment with a series of sandwich membranes shows that the principal processes governing the upper detection limit of PVC-DOS membranes are identical to those for the PVC-NPOE membranes. However, the stability of the ion pairs between the ionophore-metal ion complexes and the extracted anion are different from that of ion pairs formed between the same anion and the lipophilic anion exchanger. This makes it difficult to quantitatively predict the upper detection limit on the basis of simple apparent coextraction and complexation data alone. The approach reported herein is useful not only for mechanistic purposes but also to shed light onto the many cases where coextraction effects need to be understood but are not directly experimentally accessible.

          Related collections

          Author and article information

          Journal
          Analytical Chemistry
          Anal. Chem.
          American Chemical Society (ACS)
          0003-2700
          1520-6882
          July 2002
          July 2002
          : 74
          : 13
          : 3134-3141
          Article
          10.1021/ac0156159
          12141674
          88f9df18-9d9c-4477-9607-42cb47179b81
          © 2002
          History

          Comments

          Comment on this article