      Reevaluation of absolute luminescence quantum yields of standard solutions using a spectrometer with an integrating sphere and a back-thinned CCD detector.

      Physical Chemistry Chemical Physics
      Luminescence, Quantum Theory, Reference Standards, Solutions, Spectrometry, Fluorescence

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We reevaluate the absolute fluorescence and phosphorescence quantum yields of standard solutions by using a novel instrument developed for measuring the absolute emission quantum yields of solutions. The instrument consists of an integrating sphere equipped with a monochromatized Xe arc lamp as the light source and a multichannel spectrometer. By using a back-thinned CCD (BT-CCD) as the detector, the sensitivity for spectral detection in both the short and long wavelength regions is greatly improved compared with that of an optical detection system that uses a conventional photodetector. Using this instrument, we reevaluate the absolute fluorescence quantum yields (Phi(f)) of some commonly used fluorescence standard solutions by taking into account the effect of reabsorption/reemission. The value of Phi(f) for 5 x 10(-3) M quinine bisulfate in 1 N H(2)SO(4) is measured to be 0.52, which is in good agreement with the value (0.508) obtained by Melhuish by using a modified Vavilov method. In contrast, the value of Phi(f) for 1.0 x 10(-5) M quinine bisulfate in 1 N H(2)SO(4), which is one of the most commonly used standards in quantum yield measurements based on the relative method, is measured to be 0.60. This value is significantly larger than Melhuish's value (0.546), which was estimated by extrapolating the value of Phi(f) for 5 x 10(-3) M quinine bisulfate solution to infinite dilution using the self-quenching constant. The fluorescence quantum yield of 9,10-diphenylanthracene in cyclohexane is measured to be 0.97. This system can also be used to determine the phosphorescence quantum yields (Phi(p)) of metal complexes that emit phosphorescence in the near-infrared region: the values of Phi(p) for [Ru(bpy)(3)](2+) (bpy = 2,2'-bipyridine) are estimated to be 0.063 in water and 0.095 in acetonitrile under deaerated conditions at 298 K, while that in aerated water, which is frequently used as a luminescent reference in biological studies, is reevaluated to be 0.040.

          Related collections

          Author and article information

          Journal
          19851565
          10.1039/b912178a

          Chemistry
          Luminescence,Quantum Theory,Reference Standards,Solutions,Spectrometry, Fluorescence
          Chemistry
          Luminescence, Quantum Theory, Reference Standards, Solutions, Spectrometry, Fluorescence

          Comments

          Comment on this article