      Risk of target coverage loss for stereotactic body radiotherapy treatment of synchronous lung lesions via single‐isocenter volumetric modulated arc therapy

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Treating multiple lung lesions synchronously via single‐isocenter volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) improves treatment efficiency and patient compliance. However, aligning multiple lung tumors accurately on single pretreatment cone beam CTs (CBCTs) can be problematic. Tumors misaligned could lead to target coverage loss. To quantify this potential target coverage loss due to small, clinically realistic setup errors, a novel simulation method was developed. This method was used on 26 previously treated patients with two metastatic lung lesions. Patients were treated with 4D CT‐based, highly conformal noncoplanar VMAT plans (clinical VMAT) with 6MV‐flattening filter free (FFF) beam using AcurosXB dose calculation algorithm with heterogeneity corrections. A single isocenter was placed approximately between the lesions to improve patient convenience and clinic workflow. Average isocenter to tumor distance was 5.9 cm. Prescription dose was 54 Gy/50 Gy in 3/5 fractions. For comparison, a plan summation (simulated VMAT) was executed utilizing randomly simulated, clinically relevant setup errors, obtained from pretreatment setup, per treatment fraction, in Eclipse treatment planning system for each of the six degrees of freedom within ± 5.0 mm and ± 2°. Simulations yielded average deviations of 27.4% (up to 72% loss) ( P < 0.001) from planned target coverage when treating multiple lung lesions using a single‐isocenter plan. The largest deviations from planned coverage and desired biological effective dose (BED10, with α/β = 10 Gy) were seen for the smallest targets (<10 cc), some of which received < 100 Gy BED10. Patient misalignment resulted in substantial decrease in conformity and increase in the gradient index, violating major characteristics of SBRT. Statistically insignificant differences were seen for normal tissue dose. Although, clinical follow‐up of these patients is ongoing, the authors recommend an alternative treatment planning strategy to minimize the probability of a geometric miss when treating small lung lesions synchronously with single‐isocenter VMAT SBRT plans.

          Related collections

          Most cited references28

          • Record: found
          • Abstract: found
          • Article: not found

          Stereotactic body radiation therapy: the report of AAPM Task Group 101.

          Task Group 101 of the AAPM has prepared this report for medical physicists, clinicians, and therapists in order to outline the best practice guidelines for the external-beam radiation therapy technique referred to as stereotactic body radiation therapy (SBRT). The task group report includes a review of the literature to identify reported clinical findings and expected outcomes for this treatment modality. Information is provided for establishing a SBRT program, including protocols, equipment, resources, and QA procedures. Additionally, suggestions for developing consistent documentation for prescribing, reporting, and recording SBRT treatment delivery is provided.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Stereotactic body radiation therapy for inoperable early stage lung cancer.

            Patients with early stage but medically inoperable lung cancer have a poor rate of primary tumor control (30%-40%) and a high rate of mortality (3-year survival, 20%-35%) with current management. To evaluate the toxicity and efficacy of stereotactic body radiation therapy in a high-risk population of patients with early stage but medically inoperable lung cancer. Phase 2 North American multicenter study of patients aged 18 years or older with biopsy-proven peripheral T1-T2N0M0 non-small cell tumors (measuring <5 cm in diameter) and medical conditions precluding surgical treatment. The prescription dose was 18 Gy per fraction x 3 fractions (54 Gy total) with entire treatment lasting between 1(1/2) and 2 weeks. The study opened May 26, 2004, and closed October 13, 2006; data were analyzed through August 31, 2009. The primary end point was 2-year actuarial primary tumor control; secondary end points were disease-free survival (ie, primary tumor, involved lobe, regional, and disseminated recurrence), treatment-related toxicity, and overall survival. A total of 59 patients accrued, of which 55 were evaluable (44 patients with T1 tumors and 11 patients with T2 tumors) with a median follow-up of 34.4 months (range, 4.8-49.9 months). Only 1 patient had a primary tumor failure; the estimated 3-year primary tumor control rate was 97.6% (95% confidence interval [CI], 84.3%-99.7%). Three patients had recurrence within the involved lobe; the 3-year primary tumor and involved lobe (local) control rate was 90.6% (95% CI, 76.0%-96.5%). Two patients experienced regional failure; the local-regional control rate was 87.2% (95% CI, 71.0%-94.7%). Eleven patients experienced disseminated recurrence; the 3-year rate of disseminated failure was 22.1% (95% CI, 12.3%-37.8%). The rates for disease-free survival and overall survival at 3 years were 48.3% (95% CI, 34.4%-60.8%) and 55.8% (95% CI, 41.6%-67.9%), respectively. The median overall survival was 48.1 months (95% CI, 29.6 months to not reached). Protocol-specified treatment-related grade 3 adverse events were reported in 7 patients (12.7%; 95% CI, 9.6%-15.8%); grade 4 adverse events were reported in 2 patients (3.6%; 95% CI, 2.7%-4.5%). No grade 5 adverse events were reported. Patients with inoperable non-small cell lung cancer who received stereotactic body radiation therapy had a survival rate of 55.8% at 3 years, high rates of local tumor control, and moderate treatment-related morbidity.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Stereotactic body radiotherapy (SBRT) for operable stage I non-small-cell lung cancer: can SBRT be comparable to surgery?

              To review treatment outcomes for stereotactic body radiotherapy (SBRT) in medically operable patients with Stage I non-small-cell lung cancer (NSCLC), using a Japanese multi-institutional database. Between 1995 and 2004, a total of 87 patients with Stage I NSCLC (median age, 74 years; T1N0M0, n=65; T2N0M0, n=22) who were medically operable but refused surgery were treated using SBRT alone in 14 institutions. Stereotactic three-dimensional treatment was performed using noncoplanar dynamic arcs or multiple static ports. Total dose was 45-72.5 Gy at the isocenter, administered in 3-10 fractions. Median calculated biological effective dose was 116 Gy (range, 100-141 Gy). Data were collected and analyzed retrospectively. During follow-up (median, 55 months), cumulative local control rates for T1 and T2 tumors at 5 years after SBRT were 92% and 73%, respectively. Pulmonary complications above Grade 2 arose in 1 patient (1.1%). Five-year overall survival rates for Stage IA and IB subgroups were 72% and 62%, respectively. One patient who developed local recurrences safely underwent salvage surgery. Stereotactic body radiotherapy is safe and promising as a radical treatment for operable Stage I NSCLC. The survival rate for SBRT is potentially comparable to that for surgery. Copyright © 2011 Elsevier Inc. All rights reserved.
                Bookmark

                Author and article information

                Contributors
                damodar.pokhrel@uky.edu
                Journal
                J Appl Clin Med Phys
                J Appl Clin Med Phys
                10.1002/(ISSN)1526-9914
                ACM2
                Journal of Applied Clinical Medical Physics
                John Wiley and Sons Inc. (Hoboken )
                1526-9914
                20 December 2020
                January 2021
                : 22
                : 1 ( doiID: 10.1002/acm2.v22.1 )
                : 251-260
                Affiliations
                [ 1 ] Medical Physics Graduate Program Department of Radiation Medicine University Kentucky Lexington KY USA
                Author notes
                [*] [* ] Author to whom correspondence should be addressed. Damodar Pokhrel

                E‐mail: damodar.pokhrel@ 123456uky.edu

                Telephone no: (859) 323‐7599.

                Article
                ACM213145
                10.1002/acm2.13145
                7856510
                33342042
                95b1f0b7-8472-4ae0-aeac-805be1b4158f
                © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of American Association of Physicists in Medicine.

                This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

                History
                : 13 July 2020
                : 21 October 2020
                : 07 December 2020
                Page count
                Figures: 8, Tables: 3, Pages: 10, Words: 6915
                Categories
                Radiation Oncology Physics
                Radiation Oncology Physics
                Custom metadata
                2.0
                January 2021
                Converter:WILEY_ML3GV2_TO_JATSPMC version:5.9.7 mode:remove_FC converted:03.02.2021

                bed10,coverage loss,lung sbrt,setup errors,single‐isocenter vmat,synchronous

                Comments

                Comment on this article