          Polydimethylsiloxane (PDMS Sylgard 184, Dow Corning Corporation) pre-polymer was combined with increasing amounts of cross-linker (5.7, 10.0, 14.3, 21.4, and 42.9 wt.%) and designated PDMS1, PDMS2, PDMS3, PDMS4, and PDMS5, respectively. These materials were processed by spin coating and subjected to common micro-fabrication, micro-machining, and biomedical processes: chemical immersion, oxygen plasma treatment, sterilization, and exposure to tissue culture media. The PDMS formulations were analyzed by gravimetry, goniometry, tensile testing, nano-indentation, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS). Spin coating of PDMS was formulation dependent with film thickness ranging from 308 microm on PDMS1 to 171 microm on PDMS5 at 200 revolutions per minute (rpm). Ultimate tensile stress (UTS) increased from 3.9 MPa (PDMS1) to 10.8 MPa (PDMS3), and then decreased down to 4.0 MPa (PDMS5). Autoclave sterilization (AS) increased the storage modulus (sigma) and UTS in all formulations, with the highest increase in UTS exhibited by PDMS5 (218%). PDMS surface hydrophilicity and micro-textures were generally unaffected when exposed to the different chemicals, except for micro-texture changes after immersion in potassium hydroxide and buffered hydrofluoric, nitric, sulfuric, and hydrofluoric acids; and minimal changes in contact angle after immersion in hexane, hydrochloric acid, photoresist developer, and toluene. Oxygen plasma treatment decreased the contact angle of PDMS2 from 109 degrees to 60 degrees. Exposure to tissue culture media resulted in increased PDMS surface element concentrations of nitrogen and oxygen.

          Related collections

          Author and article information

          Journal
          Biomed Microdevices
          Biomedical microdevices
          Springer Science and Business Media LLC
          1387-2176
          1387-2176
          Dec 2005
          : 7
          : 4
          Affiliations
          [1 ] Department of Chemical and Biomedical Engineering, Cleveland State University, Cleveland, OH, 44115.
          Article
          10.1007/s10544-005-6070-2
          16404506
          9773382d-9483-4d9b-a335-b93eb6868ec3
          History

          Comments

          Comment on this article