      To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations?

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Proximal femur strength estimates from computed tomography (CT)-based finite element (FE) models are finding clinical application. Published models reached a high in-vitro accuracy, yet many of them rely on nonlinear methodologies or internal best-fitting of parameters. The aim of the present study is to verify to what extent a linear FE modelling procedure, fully based on independently determined parameters, can predict the failure characteristics of the proximal femur in stance and sideways fall loading configurations. Fourteen fresh-frozen cadaver femora were CT-scanned. Seven femora were tested to failure in stance loading conditions, and seven in fall. Fracture was monitored with high-speed videos. Linear FE models were built from CT images according to a procedure already validated in the prediction of strains. An asymmetric maximum principal strain criterion (0.73% tensile, 1.04% compressive limit) was used to define a node-based risk factor (RF). FE-predicted failure load, mode (tensile/compressive) and location were determined from the first node reaching RF=1. FE-predicted and measured failure loads were highly correlated (R(2)=0.89, SEE=814N). In all specimens, FE models correctly identified the failure mode (tensile in stance, compressive in fall) and the femoral region where fracture started (supero-lateral neck aspect). The location of failure onset was accurately predicted in eight specimens. In summary, a simple FE model, adaptable in the future to multiple loads (e.g. including muscles), was highly correlated with experimental failure in two loading conditions on specimens ranging from normal to osteoporotic. Thus, it can be suitable for use in clinical studies.

          Related collections

          Author and article information

          Journal
          J Biomech
          Journal of biomechanics
          Elsevier BV
          1873-2380
          0021-9290
          Nov 07 2014
          : 47
          : 14
          Affiliations
          [1 ] Laboratorio di Bioingegneria Computazionale, Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy. Electronic address: schileo@tecno.ior.it.
          [2 ] Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy.
          [3 ] Department of Industrial Engineering, University of Bologna, Bologna, Italy.
          Article
          S0021-9290(14)00460-6
          10.1016/j.jbiomech.2014.08.024
          25261321
          9c8f4870-80d7-495b-8ad3-91ffa5dc0a41
          History

          Bone biomechanics,Computed tomography,Proximal femur,Subject-specific finite element models,Validation

          Comments

          Comment on this article