      Fluid Dynamics of Coarctation of the Aorta and Effect of Bicuspid Aortic Valve

      research-article
      1 , 2 , 3 , * , 3 , 4 , 5 , 3
      PLoS ONE
      Public Library of Science

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Up to 80% of patients with coarctation of the aorta (COA) have a bicuspid aortic valve (BAV). Patients with COA and BAV have elevated risks of aortic complications despite successful surgical repair. The development of such complications involves the interplay between the mechanical forces applied on the artery and the biological processes occurring at the cellular level. The focus of this study is on hemodynamic modifications induced in the aorta in the presence of a COA and a BAV. For this purpose, numerical investigations and magnetic resonance imaging measurements were conducted with different configurations: (1) normal: normal aorta and normal aortic valve; (2) isolated COA: aorta with COA (75% reduction by area) and normal aortic valve; (3) complex COA: aorta with the same severity of COA (75% reduction by area) and BAV. The results show that the coexistence of COA and BAV significantly alters blood flow in the aorta with a significant increase in the maximal velocity, secondary flow, pressure loss, time-averaged wall shear stress and oscillatory shear index downstream of the COA. These findings can contribute to a better understanding of why patients with complex COA have adverse outcome even following a successful surgery.

          Related collections

          Most cited references42

          • Record: found
          • Abstract: found
          • Article: not found

          A classification system for the bicuspid aortic valve from 304 surgical specimens.

          In general, classification of a disease has proven to be advantageous for disease management. This may also be valid for the bicuspid aortic valve, because the term "bicuspid aortic valve" stands for a common congenital aortic valve malformation with heterogeneous morphologic phenotypes and function resulting in different treatment strategies. We attempted to establish a classification system based on a 5-year data collection of surgical specimens. Between 1999 and 2003 a precise description of valve pathology was obtained from operative reports of 304 patients with a diseased bicuspid aortic valve. Several different characteristics of bicuspid aortic valves were tested to generate a pithy and easily applicable classification system. Three characteristics for a systematic classification were found appropriate: (1) number of raphes, (2) spatial position of cusps or raphes, and (3) functional status of the valve. The first characteristic was found to be the most significant and therefore termed "type." Three major types were identified: type 0 (no raphe), type 1 (one raphe), and type 2 (two raphes), followed by two supplementary characteristics, spatial position and function. These characteristics served to classify and codify the bicuspid aortic valves into three categories. Most frequently, a bicuspid aortic valve with one raphe was identified (type 1, n = 269). This raphe was positioned between the left (L) and right (R) coronary sinuses in 216 (type 1, L/R) with a hemodynamic predominant stenosis (S) in 119 (type 1, L/R, S). Only 21 patients had a "purely" bicuspid aortic valve with no raphe (type 0). A classification system for the bicuspid aortic valve with one major category ("type") and two supplementary categories is presented. This classification, even if used in the major category (type) alone, might be advantageous to better define bicuspid aortic valve disease, facilitate scientific communication, and improve treatment.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Bicuspid aortic valve: four-dimensional MR evaluation of ascending aortic systolic flow patterns.

            To use time-resolved three-dimensional phase-contrast magnetic resonance (MR) imaging, also called four-dimensional flow MR imaging, to evaluate systolic blood flow patterns in the ascending aorta that may predispose patients with a bicuspid aortic valve (BAV) to aneurysm. The HIPAA-compliant protocol received institutional review board approval, and informed consent was obtained. Four-dimensional flow MR imaging was used to assess blood flow in the thoracic aorta of 53 individuals: 20 patients with a BAV, 25 patients with a tricuspid aortic valve (TAV), and eight healthy volunteers. The Fisher exact test was used to evaluate the significance of flow pattern differences. Nested helical flow was seen at peak systole in the ascending aorta of 15 of 20 patients with a BAV but in none of the healthy volunteers or patients with a TAV. This flow pattern was seen both in patients with a BAV with a dilated ascending aorta (n = 6) and in those with a normal ascending aorta (n = 9), was seen in the absence of aortic stenosis (n = 5), and was associated with eccentric systolic flow jets in all cases. Fusion of right and left leaflets gave rise to right-handed helical flow and right-anterior flow jets (n = 11), whereas right and noncoronary fusion gave rise to left-handed helical flow with left-posterior flow jets (n = 4). Four-dimensional flow MR imaging showed abnormal helical systolic flow in the ascending aorta of patients with a BAV, including those without aneurysm or aortic stenosis. Identification and characterization of eccentric flow jets in these patients may help identify those at risk for development of ascending aortic aneurysm. RSNA, 2010
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              On coupling a lumped parameter heart model and a three-dimensional finite element aorta model.

              Aortic flow and pressure result from the interactions between the heart and arterial system. In this work, we considered these interactions by utilizing a lumped parameter heart model as an inflow boundary condition for three-dimensional finite element simulations of aortic blood flow and vessel wall dynamics. The ventricular pressure-volume behavior of the lumped parameter heart model is approximated using a time varying elastance function scaled from a normalized elastance function. When the aortic valve is open, the coupled multidomain method is used to strongly couple the lumped parameter heart model and three-dimensional arterial models and compute ventricular volume, ventricular pressure, aortic flow, and aortic pressure. The shape of the velocity profiles of the inlet boundary and the outlet boundaries that experience retrograde flow are constrained to achieve a robust algorithm. When the aortic valve is closed, the inflow boundary condition is switched to a zero velocity Dirichlet condition. With this method, we obtain physiologically realistic aortic flow and pressure waveforms. We demonstrate this method in a patient-specific model of a normal human thoracic aorta under rest and exercise conditions and an aortic coarctation model under pre- and post-interventions.
                Bookmark

                Author and article information

                Contributors
                Role: Editor
                Journal
                PLoS One
                PLoS ONE
                plos
                plosone
                PLoS ONE
                Public Library of Science (San Francisco, USA )
                1932-6203
                2013
                27 August 2013
                : 8
                : 8
                : e72394
                Affiliations
                [1 ]Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada
                [2 ]Biomedical Engineering Department, University of Montreal, Montréal, Québec, Canada
                [3 ]Laboratory of Cardiovascular Fluid Dynamics, Mechanical and Industrial Engineering Department, Concordia University, Montréal, Québec, Canada
                [4 ]Québec Heart and Lung Institute, Laval University, Québec, Québec, Canada
                [5 ]Department of Radiology, Northwestern University, Chicago, Illinois, United States of America
                University of California, San Diego, United States of America
                Author notes

                Competing Interests: The authors have declared that no competing interests exist.

                Conceived and designed the experiments: ZKM LK. Performed the experiments: ZKM JG. Analyzed the data: ZKM JG. Contributed reagents/materials/analysis tools: ZKM JG LK. Wrote the paper: ZKM LK.

                Article
                PONE-D-13-14457
                10.1371/journal.pone.0072394
                3754982
                24015239
                ce9e24ed-b2d2-415d-90ba-0cca4e9a0e9b
                Copyright @ 2013

                This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

                History
                : 9 April 2013
                : 10 July 2013
                Page count
                Pages: 14
                Funding
                The authors have no support or funding to report.
                Categories
                Research Article
                Biology
                Anatomy and Physiology
                Cardiovascular System
                Circulatory Physiology
                Biophysics
                Biomechanics
                Biological Fluid Mechanics
                Biophysics Simulations
                Biotechnology
                Bioengineering
                Biomedical Engineering
                Computational Biology
                Biophysic Al Simulations
                Engineering
                Bioengineering
                Biomedical Engineering
                Medicine
                Cardiovascular
                Hemodynamics
                Drugs and Devices
                Adverse Reactions
                Radiology
                Diagnostic Radiology
                Magnetic Resonance Imaging
                Physics
                Biophysics
                Biomechanics
                Biological Fluid Mechanics
                Biophysics Simulations

                Uncategorized
                Uncategorized

                Comments

                Comment on this article