9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Left atrial remodelling in patients undergoing transcatheter aortic valve implantation: a speckle-tracking prospective, longitudinal study.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Aortic stenosis (AS) results in several left ventricular (LV) disturbances as well as progressive left atrial (LA) enlargement and dysfunction. Transcatheter aortic valve implantation (TAVI) reverses LV remodelling and improves overall systolic function but its effect on LA function remains undetermined. The aim of this prospective, longitudinal study was to investigate the effects of TAVI on LA structure and function. We studied thirty-two patients with severe symptomatic AS who underwent TAVI, using standard and 2-dimensional speckle-tracking echocardiography before, at 40-day and at 3-month follow-up. Following TAVI, mean transvalvular gradient decreased (p < 0.001). Both LA area index and LA volume index decreased at 40-day follow-up (16.2 ± 6.4 vs. 12.5 ± 2.9 cm2/m2, and 47.3 ± 12.0 vs. 42.8 ± 12.5 mL/m2, respectively, p < 0.05) and values remained unchanged at 3 months. The reduction of LA size was accompanied by a significant increase in global peak atrial longitudinal strain (14.4 ± 3.9 vs. 19.1 ± 4.7%, p < 0.001) and in global peak atrial contraction strain (8.4 ± 2.5 vs. 11.0 ± 4.1%, p < 0.05) at 3-month follow-up. LA stiffness measurements significantly decreased 3 months after TAVI (0.93 ± 0.59 vs. 0.65 ± 0.37, respectively, p < 0.001). Trans-aortic mean gradient change and pre-procedural LA volume were identified as predictors of global peak atrial longitudinal strain increase (β = -0.41, β = -0.35, respectively, p < 0.0001) while pre-procedural LA volume and trans-aortic mean gradient change as predictor of LA volume index reduction 3 months after TAVI (β = -0.37, β = -0.28, respectively, p < 0.0001). TAVI is associated with significant recovery of LA structure and function suggesting a reverse cavity remodelling. Such functional recovery is primarily determined by the severity of pre-procedural valve stenosis.

          Related collections

          Author and article information

          Journal
          Int J Cardiovasc Imaging
          The international journal of cardiovascular imaging
          1875-8312
          1569-5794
          Dec 2013
          : 29
          : 8
          Affiliations
          [1 ] Department of Cardiovascular Diseases, University Hospital Santa Maria Alle Scotte, viale M. Bracci, 16, 53100, Siena, Italy, flavio.dascenzi@libero.it.
          Article
          10.1007/s10554-013-0265-z
          23852277
          d3abb280-048b-495f-9832-9c542f35a98d
          History

          Comments

          Comment on this article