5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Liner dissociation in a large-diameter ceramic-bearing acetabular component: a report of five cases

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Ceramic-on-ceramic (CoC) bearings for total hip arthroplasty (THA) have been offering very favorable results and survivorship since their introduction. In order to increase range of movement (ROM) and decrease dislocation rates, some manufacturers have introduced larger diameter head (LDH) CoC bearings. This has been achieved with the use of preassembled cup designs, in which the ceramic liner is already fitted into the metal backing and implanted as a monoblock component by the surgeon. In this report we present data from a series of 5 patients with ceramic liner dissociation from a monoblock cup.

          Case presentation

          All cases were overweight men with acetabular components of 56 or 58 mm. After a mean of 5.5 (range, 3.5-6.7) years, all patients reported sudden pain and audible noise when performing activities of daily living. Liner displacement was suspected on plain radiographs and confirmed by Ct-scan. Pneumarthrosis was present in all cases. Taper modular junction wear and corrosion signs were observed in the four revised patients.

          Conclusion

          Although one of our case is still treated conservatively, implant revision is probably inevitable. Further LDH CoC implant design should take in consideration this potential complication by avoiding bearing diameters over 40mm and/or improving locking mechanism or by providing a real monoblock acetabular implant.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          Ceramic-on-ceramic bearing fractures in total hip arthroplasty: an analysis of data from the National Joint Registry.

          Ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) are commonly used, but concerns exist regarding ceramic fracture. This study aims to report the risk of revision for fracture of modern CoC bearings and identify factors that might influence this risk, using data from the National Joint Registry (NJR) for England, Wales, Northern Ireland and the Isle of Man.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The incidence of noise generation arising from the large-diameter Delta Motion ceramic total hip bearing.

            Noise generation has been reported with ceramic-on-ceramic articulations in total hip replacement (THR). This study evaluated 208 consecutive Delta Motion THRs at a mean follow-up of 21 months (12 to 35). There were 141 women and 67 men with a mean age of 59 years (22 to 84). Patients were reviewed clinically and radiologically, and the incidence of noise was determined using a newly described assessment method. Noise production was examined against range of movement, ligamentous laxity, patient-reported outcome scores, activity level and orientation of the acetabular component. There were 143 silent hips (69%), 22 (11%) with noises other than squeaking, 17 (8%) with unreproducible squeaking and 26 (13%) with reproducible squeaking. Hips with reproducible squeaking had a greater mean range of movement (p < 0.001) and mean ligament laxity (p = 0.004), smaller median head size (p = 0.01) and decreased mean acetabular component inclination (p = 0.02) and anteversion angle (p = 0.02) compared with the other groups. There was no relationship between squeaking and age (p = 0.13), height (p = 0.263), weight (p = 0.333), body mass index (p = 0.643), gender (p = 0.07) or patient outcome score (p = 0.422). There were no revisions during follow-up. Despite the surprisingly high incidence of squeaking, all patients remain satisfied with their hip replacement.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Squeaking in Large Diameter Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty

                Bookmark

                Author and article information

                Contributors
                lazaros.kostretzis@gmail.com
                sagimartinov@gmail.com
                lavigma2@hotmail.com
                vincent.masse@me.com
                pa.vendittoli@me.com
                Journal
                BMC Musculoskelet Disord
                BMC Musculoskelet Disord
                BMC Musculoskeletal Disorders
                BioMed Central (London )
                1471-2474
                9 February 2022
                9 February 2022
                2022
                : 23
                : 136
                Affiliations
                [1 ]GRID grid.14848.31, ISNI 0000 0001 2292 3357, Surgery Department, Hôpital Maisonneuve-Rosemont, , Montreal University, ; 5415 Boulevard de l’Assomption, Montréal, Québec H1T 2M4 Canada
                [2 ]Clinique Orthopédique Duval, Laval, QC Canada
                Author information
                http://orcid.org/0000-0003-4652-6238
                Article
                5082
                10.1186/s12891-022-05082-6
                8829977
                dc416165-2882-46c5-b26f-b57b087c81a9
                © The Author(s) 2022

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 29 September 2021
                : 2 February 2022
                Categories
                Case Report
                Custom metadata
                © The Author(s) 2022

                Orthopedics
                total hip arthroplasty,ceramic liner,dissociation,monoblock acetabular component
                Orthopedics
                total hip arthroplasty, ceramic liner, dissociation, monoblock acetabular component

                Comments

                Comment on this article