      Comparison of the Antiseptic Efficacy of Tissue-Tolerable Plasma and an Octenidine Hydrochloride-Based Wound Antiseptic on Human Skin

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Colonization and infection of wounds represent a major reason for the impairment of tissue repair. Recently, it has been reported that tissue-tolerable plasma (TTP) is highly efficient in the reduction of the bacterial load of the skin. In the present study, the antiseptic efficacy of TTP was compared to that of octenidine hydrochloride with 2-phenoxyethanol. Both antiseptic methods proved to be highly efficient. Cutaneous treatment of the skin with octenidine hydrochloride and 2-phenoxyethanol leads to a 99% elimination of the bacteria, and 74% elimination is achieved by TTP treatment. Technical challenges with an early prototype TTP device could be held responsible for the slightly reduced antiseptic properties of TTP, compared to a standard antiseptic solution, since the manual treatment of the skin surface with a small beam of the TTP device might have led to an incomplete coverage of the treated area.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: found
          • Article: not found

          Non-thermal plasma technologies: new tools for bio-decontamination.

          Bacterial control and decontamination are crucial to industrial safety assessments. However, most recently developed materials are not compatible with standard heat sterilization treatments. Advanced oxidation processes, and particularly non-thermal plasmas, are emerging and promising technologies for sanitation because they are both efficient and cheap. The applications of non-thermal plasma to bacterial control remain poorly known for several reasons: this technique was not developed for biological applications and most of the literature is in the fields of physics and chemistry. Moreover, the diversity of the devices and complexity of the plasmas made any general evaluation of the potential of the technique difficult. Finally, no experimental equipment for non-thermal plasma sterilization is commercially available and reference articles for microbiologists are rare. The present review aims to give an overview of the principles of action and applications of plasma technologies in biodecontamination.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Bactericidal effects of non-thermal argon plasma in vitro, in biofilms and in the animal model of infected wounds.

            Non-thermal (low-temperature) physical plasma is under intensive study as an alternative approach to control superficial wound and skin infections when the effectiveness of chemical agents is weak due to natural pathogen or biofilm resistance. The purpose of this study was to test the individual susceptibility of pathogenic bacteria to non-thermal argon plasma and to measure the effectiveness of plasma treatments against bacteria in biofilms and on wound surfaces. Overall, Gram-negative bacteria were more susceptible to plasma treatment than Gram-positive bacteria. For the Gram-negative bacteria Pseudomonas aeruginosa, Burkholderia cenocepacia and Escherichia coli, there were no survivors among the initial 10(5) c.f.u. after a 5 min plasma treatment. The susceptibility of Gram-positive bacteria was species- and strain-specific. Streptococcus pyogenes was the most resistant with 17 % survival of the initial 10(5) c.f.u. after a 5 min plasma treatment. Staphylococcus aureus had a strain-dependent resistance with 0 and 10 % survival from 10(5) c.f.u. of the Sa 78 and ATCC 6538 strains, respectively. Staphylococcus epidermidis and Enterococcus faecium had medium resistance. Non-ionized argon gas was not bactericidal. Biofilms partly protected bacteria, with the efficiency of protection dependent on biofilm thickness. Bacteria in deeper biofilm layers survived better after the plasma treatment. A rat model of a superficial slash wound infected with P. aeruginosa and the plasma-sensitive Staphylococcus aureus strain Sa 78 was used to assess the efficiency of argon plasma treatment. A 10 min treatment significantly reduced bacterial loads on the wound surface. A 5-day course of daily plasma treatments eliminated P. aeruginosa from the plasma-treated animals 2 days earlier than from the control ones. A statistically significant increase in the rate of wound closure was observed in plasma-treated animals after the third day of the course. Wound healing in plasma-treated animals slowed down after the course had been completed. Overall, the results show considerable potential for non-thermal argon plasma in eliminating pathogenic bacteria from biofilms and wound surfaces.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found

              Octenidine Dihydrochloride, a Modern Antiseptic for Skin, Mucous Membranes and Wounds

              Octenidine dihydrochloride (octenidine) was introduced for skin, mucous membrane and wound antisepsis more than 20 years ago. Until now, a wealth of knowledge has been gained, including in vitro and animal studies on efficacy, tolerance, safety and clinical experience both from case reports and prospective controlled trials. Nowadays, octenidine is an established antiseptic in a large field of applications and represents an alternative to older substances such as chlorhexidine, polyvidone-iodine or triclosan. The review is based on the current literature and unpublished original data as well.
                Bookmark

                Author and article information

                Journal
                SPP
                Skin Pharmacol Physiol
                10.1159/issn.1660-5527
                Skin Pharmacology and Physiology
                S. Karger AG
                1660-5527
                1660-5535
                2012
                February 2012
                01 February 2012
                : 25
                : 2
                : 100-106
                Affiliations
                aDepartment of Dermatology, Venerology and Allergology, Charité – Universitätsmedizin Berlin, and bBurncenter, Traumacenter Berlin, Berlin, and cInstitute of Hygiene and Environmental Medicine, University Medicine, University of Greifswald, and dLeibniz Institute for Plasma Science and Technology e.V., Greifswald, Germany
                Author notes
                *Dr. Alexa Patzelt, Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Charité – Universitätsmedizin Berlin, Charitéplatz 1, DE–10117 Berlin (Germany), Tel. +49 30 450 518 106, E-Mail alexa.patzelt@charite.de
                Article
                335558 Skin Pharmacol Physiol 2012;25:100–106
                10.1159/000335558
                22301799
                3ae68902-808b-431d-aff2-cd7b1285a5d5
                © 2012 S. Karger AG, Basel

                Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

                History
                : 01 September 2011
                : 06 December 2011
                Page count
                Figures: 4, Pages: 7
                Categories
                Original Paper

                Oncology & Radiotherapy,Pathology,Surgery,Dermatology,Pharmacology & Pharmaceutical medicine
                Antioxidants,Octenidine dihydrochloride,Plasma treatment in vivo,Antiseptic efficacy,2-Phenoxyethanol,Skin barrier

                Comments

                Comment on this article