      Temperature response to cold challenge and mobile phone thermography as outcome measures for systemic sclerosis-related Raynaud's phenomenon.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objectives: Objective outcome measures of systemic sclerosis (SSc)-related Raynaud's phenomenon (RP) are badly needed. Our objectives were to validate the thermographic response to a standard hand cold challenge as an outcome measure by assessing sensitivity to change, and to explore mobile phone thermography as a feasible, ambulatory tool.Method: Twelve patients with an SSc-spectrum disorder admitted for intravenous iloprost infusions underwent a standard cold challenge before and after one infusion. Thermographic measurements included area under the rewarming curve (AUC) and maximum rewarming temperature (MAX). Before and during another infusion, each patient underwent monitoring of finger skin temperature by two methods: continuous thermocouple recording (standard method) and mobile phone thermography.Results: All cold challenge summary measures, including AUC and MAX, increased after iloprost (most not significantly). However, when the response curves were modelled after averaging across fingers (linear mixed models, three versions), significant change was detected. For example, with Model 1 (no interaction between period and time), temperature was on average 1.67ºC [95% confidence interval (CI) 1.49-1.85, p < 0.001] higher post-iloprost. Mobile phone and thermocouple temperature measurements showed a strong estimated latent correlation (0.88, 95% CI 0.81-0.92). The estimated increases/hour were 0.25ºC (95% CI 0.05-0.45) for the thermocouple and 0.36ºC (95% CI 0.13-0.60) for mobile phone thermography.Conclusion: Our pilot study suggests that the thermographic response to a cold challenge is sensitive to change and mobile phone thermography could bring feasibility to thermographic parameters as outcome measures in later-phase, large-scale, community-based clinical trials of RP.

          Related collections

          Author and article information

          Journal
          Scand J Rheumatol
          Scandinavian journal of rheumatology
          Informa UK Limited
          1502-7732
          0300-9742
          Nov 2021
          : 50
          : 6
          Affiliations
          [1 ] Division of Musculoskeletal and Dermatological Sciences, The University of Manchester, Salford Royal NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK.
          [2 ] Centre for Biostatistics, Manchester Academic Health Science Centre, The University of Manchester, Manchester, UK.
          [3 ] Rheumatology Unit, Department of Medicine, Solna, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden.
          Article
          10.1080/03009742.2021.1907926
          34132168
          54c8c969-503c-4685-91df-772f1e736602
          History

          Comments

          Comment on this article