9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Cold-induced vasodilation during continuous exercise in the extreme cold air (-30.6 °c)

      abstract
      1 , , 2 , 1 , 1
      Extreme Physiology & Medicine
      BioMed Central
      15th International Conference on Environmental Ergonomics (ICEE XV)
      28 June-3 July 2015

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction Cold induced vasodilation (CIVD) in previous studies was mostly evoked by cold water immersion at 0, 5, and 8 °C of the upper or lower extremities without performing physical work [1]. A limited number of investigations incorporated intermittent exercises during cold air exposure [2]. Literature has documented that the CIVD occurrence depended on the body core temperature [2], [3]. It was observed that CIVD in cold water immersion was highly variable across the fingers and was not a generalizable response across fingers or toes [4]. However, the number of studies on cold air induced vasodilation in the extremely cold is limited. The objective of this study was to investigate individual variations of finger CIVD in relation to the core and mean skin temperatures during continuous exercise in the extreme cold air (-30.6 °C). Methods Four young and healthy male subjects wore cold protective clothing ensemble (Icl = 1.89 clo) and walked at 4 MET (232.8 W/m2) on a treadmill in a climatic chamber (Ta = -30.6 C, Va = 0.4 m/s) for 90 min [5]. Hestra wind stopper fleece fabric gloves (relatively thin) were used. The core and skin temperatures were measured respectively in the rectum 10 cm above the anal sphincter, and on the forehead and left side of the body on the upper arm, forearm, hand, little finger, chest, scapula, thigh, calf, and little toe. The mean skin temperature (Tsk ) was calculated below. T s k = 0 . 07 ( T _ f o r e h e a d + T _ u p p e r a r m + T _ f o r e a r m ) + 0 . 175 ( T _ c h e s t + T _ s c a p u l a ) + 0 . 05 T _ h a n d + 0 . 19 T _ t h i g h + 0 . 20 T _ c a l f Results CIVD in the little finger occurred when the subjects' rectal temperatures (Tre) were relatively stable in the range of 37.1 - 38.1 °C and the Tsk in the range of 32.0 - 25.3 °C. Within these ranges, the finger CIVD periodical responses were not dependent on the Tre and Tsk changes. The onset time, Tmin, Tmax and Tfinger_mean, amplitude (Tmax - Tmin), frequency (number of waves) of the CIVD were 14.6 (3.5) min, 3.8 (3.4) °C, 16.5 (3.6) °C, 7.9 (1.4) °C, 12.7 (4.4) °C, 7.5 (4.7) respectively. Discussion The finger CIVD appeared in all four subjects. However, the onset time, minimum, maximum and mean finger temperatures, amplitude, frequency of the CIVD varied among the four subjects. The finger CIVD occurred when the mean finger temperatures of the four subjects were below 10 °C, thus it seems to be related to the local cooling of the extremities during continuous and stable exercise at high metabolic rate in the extremely cold environment. The CIVD in toes was not as clear as in the fingers, which might be attributed to the continuous walking. Conclusion The finger CIVD varies among the subjects. Its occurrence is not dependent on Tre and Tsk changes within the Tre and Tsk ranges (37.1 - 38.1 °C and 32.0 - 25.3 °C), but it is associated with the local cooling of the extremities during continuous 90 min walking at 4 MET in the extreme cold air (-30.6 °C).

          Related collections

          Author and article information

          Contributors
          Conference
          Extrem Physiol Med
          Extrem Physiol Med
          Extreme Physiology & Medicine
          BioMed Central
          2046-7648
          2015
          14 September 2015
          : 4
          : Suppl 1
          : A58
          Affiliations
          [1 ]Thermal Environment Laboratory, Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Faculty of Engineering, Lund University, Box 118, 221 00 Lund, Sweden
          [2 ]Department of Testing and Certification, Taiwan Textile Research Institute (TTRI), 6 Chengtian Road, Tucheng District, New Taipei, 23674, Taiwan
          Article
          2046-7648-4-S1-A58
          10.1186/2046-7648-4-S1-A58
          4580801
          f4144209-eeb0-47a8-80e9-55b15263b9d7
          Copyright © 2015 Gao et al.

          This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

          15th International Conference on Environmental Ergonomics (ICEE XV)
          Portsmouth, UK
          28 June-3 July 2015
          History
          Categories
          Meeting Abstract

          Comments

          Comment on this article