2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Impulse oscillometry for detection of small airway dysfunction in subjects with chronic respiratory symptoms and preserved pulmonary function

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Subjects with chronic respiratory symptoms and preserved pulmonary function (PPF) may have small airway dysfunction (SAD). As the most common means to detect SAD, spirometry needs good cooperation and its reliability is controversial. Impulse oscillometry (IOS) may complete the deficiency of spirometry and have higher sensitivity. We aimed to explore the diagnostic value of IOS to detect SAD in symptomatic subjects with PPF.

          Methods

          The evaluation of symptoms, spirometry and IOS results in 209 subjects with chronic respiratory symptoms and PPF were assessed. ROC curves of IOS to detect SAD were analyzed.

          Results

          209 subjects with chronic respiratory symptoms and PPF were included. Subjects who reported sputum had higher R5–R20 and Fres than those who didn’t. Subjects with dyspnea had higher R5, R5–R20 and AX than those without. CAT and mMRC scores correlated better with IOS parameters than with spirometry. R5, R5–R20, AX and Fres in subjects with SAD (n = 42) significantly increased compared to those without. Cutoff values for IOS parameters to detect SAD were 0.30 kPa/L s for R5, 0.015 kPa/L s for R5–R20, 0.30 kPa/L for AX and 11.23 Hz for Fres. Fres has the largest AUC (0.665, P = 0.001) among these parameters. Compared with spirometry, prevalence of SAD was higher when measured with IOS. R5 could detect the most SAD subjects with a prevalence of 60.77% and a sensitivity of 81% (AUC = 0.659, P = 0.002).

          Conclusion

          IOS is more sensitive to detect SAD than spirometry in subjects with chronic respiratory symptoms and PPF, and it correlates better with symptoms. IOS could be an additional method for SAD detection in the early stage of diseases.

          Related collections

          Most cited references29

          • Record: found
          • Abstract: found
          • Article: not found

          Standardization of Spirometry 2019 Update. An Official American Thoracic Society and European Respiratory Society Technical Statement

          Background: Spirometry is the most common pulmonary function test. It is widely used in the assessment of lung function to provide objective information used in the diagnosis of lung diseases and monitoring lung health. In 2005, the American Thoracic Society and the European Respiratory Society jointly adopted technical standards for conducting spirometry. Improvements in instrumentation and computational capabilities, together with new research studies and enhanced quality assurance approaches, have led to the need to update the 2005 technical standards for spirometry to take full advantage of current technical capabilities. Methods: This spirometry technical standards document was developed by an international joint task force, appointed by the American Thoracic Society and the European Respiratory Society, with expertise in conducting and analyzing pulmonary function tests, laboratory quality assurance, and developing international standards. A comprehensive review of published evidence was performed. A patient survey was developed to capture patients’ experiences. Results: Revisions to the 2005 technical standards for spirometry were made, including the addition of factors that were not previously considered. Evidence to support the revisions was cited when applicable. The experience and expertise of task force members were used to develop recommended best practices. Conclusions: Standards and consensus recommendations are presented for manufacturers, clinicians, operators, and researchers with the aims of increasing the accuracy, precision, and quality of spirometric measurements and improving the patient experience. A comprehensive guide to aid in the implementation of these standards was developed as an online supplement.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Clinical Significance of Symptoms in Smokers with Preserved Pulmonary Function.

            Currently, the diagnosis of chronic obstructive pulmonary disease (COPD) requires a ratio of forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC) of less than 0.70 as assessed by spirometry after bronchodilator use. However, many smokers who do not meet this definition have respiratory symptoms.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Technical standards for respiratory oscillometry

              Oscillometry (also known as the forced oscillation technique) measures the mechanical properties of the respiratory system (upper and intrathoracic airways, lung tissue and chest wall) during quiet tidal breathing, by the application of an oscillating pressure signal (input or forcing signal), most commonly at the mouth. With increased clinical and research use, it is critical that all technical details of the hardware design, signal processing and analyses, and testing protocols are transparent and clearly reported to allow standardisation, comparison and replication of clinical and research studies. Because of this need, an update of the 2003 European Respiratory Society (ERS) technical standards document was produced by an ERS task force of experts who are active in clinical oscillometry research. The aim of the task force was to provide technical recommendations regarding oscillometry measurement including hardware, software, testing protocols and quality control. The main changes in this update, compared with the 2003 ERS task force document are 1) new quality control procedures which reflect use of “within-breath” analysis, and methods of handling artefacts; 2) recommendation to disclose signal processing, quality control, artefact handling and breathing protocols ( e.g. number and duration of acquisitions) in reports and publications to allow comparability and replication between devices and laboratories; 3) a summary review of new data to support threshold values for bronchodilator and bronchial challenge tests; and 4) updated list of predicted impedance values in adults and children.
                Bookmark

                Author and article information

                Contributors
                fengmingluo@outlook.com
                Journal
                Respir Res
                Respir Res
                Respiratory Research
                BioMed Central (London )
                1465-9921
                1465-993X
                24 February 2021
                24 February 2021
                2021
                : 22
                : 68
                Affiliations
                [1 ]GRID grid.13291.38, ISNI 0000 0001 0807 1581, Department of Respiratory and Critical Care Medicine, , West China School of Medicine and West China Hospital, Sichuan University, ; No. 37 Guoxue Alley, Chengdu, 610041 China
                [2 ]GRID grid.13291.38, ISNI 0000 0001 0807 1581, Department of Critical Care Medicine, , West China School of Medicine and West China Hospital, Sichuan University, ; Chengdu, 610041 China
                Author information
                http://orcid.org/0000-0001-9267-3437
                Article
                1662
                10.1186/s12931-021-01662-7
                7903610
                33627138
                2008b76f-59b7-43e2-a235-5ea9bf203748
                © The Author(s) 2021

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 28 November 2020
                : 11 February 2021
                Funding
                Funded by: National Nature Science Foundation of China grant
                Award ID: NSFC No.81800016
                Award Recipient :
                Funded by: 1.3.5 project for disciplines of excellence, West China Hospital, Sichuan University
                Award ID: ZYJC18021
                Award Recipient :
                Funded by: Chengdu Science and Technology Bureau
                Award ID: No. 2018-CY02-00064-GX
                Award Recipient :
                Funded by: Sichuan Science and Technology Agency Grant
                Award ID: 2019YFS0033
                Award Recipient :
                Categories
                Research
                Custom metadata
                © The Author(s) 2021

                Respiratory medicine
                small airway dysfunction,spirometry,impulse oscillometry,preserved pulmonary function

                Comments

                Comment on this article